S811 soft starter user manual

Catalog number selection s801 open soft starters 12 notes. The starters feature edgelevel sensing control, builtin communication using the eaton quick connect port, advanced diagnostics capabilities fault queue, control status, and breaker status, and an impressive array of system monitoring and. Our soft starters can be easily integrated into your intelligent motor control solution to offer higher productivity and shorter downtimes. Internal solidstate overload protection, run bypass. Bbv530 092015 7 steps for setting up the soft starter also refer to quick start guide 1. P and hand inputs must be energized 24v dc to enable starting of the soft starter from the terminal block. The builtin solidstate overload protects the motor from overload conditions with sophisticated algorithms that. They feature compact, true threephase control in a costeffective package. These starters will ignore a run command if that jumper is not there. See the user manual link below for fault listings and a troubleshooting guide. The s811 soft starters are available in different starting modes, including the voltage ramp start and the current limit start. V6t1124 type s801, soft starters product description eatons s801 line of reduced voltage soft starters is very compact, multifunctional, easy to install and easy to program. Make sure you read and understand the procedures in this manual before. Soft starters, low voltage our smart motor controllers are soft starters that are designed to help minimize cost by reducing overall system power requirements and wear and tear on equipment.

The insidethedelta user manual can be found by searching for pub. The information contained in this manual is subject to change without notice. To provide optimum motor protection the line and motor power wiring should be tightly bundled and run perpendicular to the orientation of the s811. S811 starter adds communications capabilities via a digital interface module dim that includes an easy to use operator interface, according to partain. This includes the user manual, instruction leaflets, trip curves, brochures, product aids, application notes, software downloads, and cad files. The motor can be started in either voltage ramp start or current limit start mode. The sole source governing the rights and remedies of any. If the fault flags is cleared, the soft starter checks again in five seconds to make sure it stays clear.

Uc 24 v dc, assigned motor rating standard connection, inline at 400 v, 50 hz. Ambient temperature does not affect soft starter function within its operating limits. Soft starter basic operation soft starter motor soft. Internal solidstate overload protection, run bypass mode and lugs.

Jun 02, 2011 eaton cutlerhammer s811 soft starter fault indication. Eaton cutlerhammer s811 soft starter fault indication tristate electrical supplys channel. This guide is intended to provide the information necessary. Soft starter safety statements the following safety statements relate to the installation, operation and troubleshooting of cutlerhammer motor starters. The unit is solid state, using a microprocessor to control inverse parallel back to back pairs of scrs. Wiring the altistart 22 soft starter w s6u suffix for 2 wire control. Apply 24v dc to input 1 while the p input is energized. Any differences and special features of the individual ratings and frame sizes are noted accordingly. However, we wish to point out how to safely operate and troubleshoot your starter.

Please refer to sizing charts in product user manual, mn03902002e, or call 877etncare 3862273 for assistance in sizing a soft starter for specific. When a fault is present, the autoreset will attempt to reset the fault every 2. If the instructions in this manual are followed, the pstx softstarter will have the most important features. Eaton cutlerhammer s801 soft start fault indication youtube. Besides supporting a wide main voltage range of 208600v, its internal circuit board is coated to prevent the effect of corrosion, dust and moisture. Mn03902008e june 2006 safety eatons electrical business has made every effort to provide you with the safest motor starters on the market. Prolonged service intervals and reduced cost of ownership are additional advantages. However, click on the respective links below and you will be taken directly to the manuals. Our smc3 soft starters are available with a current range from 3.

Soft starter for threephase loads, with control unit, mains supply voltage 5060 hz. Please refer to sizing charts in product user manual, mn03902002e, or call 877 etncare 3862273 for assistance in sizing a soft starter for specific. S801 soft starter user manual vi for more information visit. Receive and inspect the soft starter v check that the soft starter reference on the nameplate is similar to the purchase order. Control engineering starting, stopping motors softly. Effective may 2012 installation leafl et il03900005e. Type s811, soft starters with dim starting and stopping modes the s811 has a variety of starting and stopping methods to provide superior performance in the most demanding applications. Starters best in customer satisfaction in march 2004. This pro tects the motor and power wiring against overheating caused by excessive. The s811 soft starters come with a ton of features and they are available in different specifications.

Read the message and follow the instructions carefully. Line connected soft starter power wiring diagram figure 8. It calls your attention to items or operations that could be dangerous to you and other persons operating this equipment. Eaton cutlerhammer soft start starters for pump applications. Eaton cutlerhammer s801 soft start fault indication. They include overload protection, integral bypass, and motor and system diagnostics. With this small size, it can easily fit in place of existing soft starter designs, wyedelta starters or acrosstheline nema and iec starters. Eliminating abrupt starts and stops, extending mechanical. The edgesensing feature allows for a motor restart when a fault condition is cleared, the permissive terminal is supplied with 24 volts dc, and the reset mode parameter is set to auto or manual. Eaton s811n66n3s s811 series, softstarter, 66 amp s811 series communicating softstarter. Our product manuals can be found using the search function on our electrical website. Eaton cutlerhammer s811 soft starter fault indication. Soft starter basic operation soft starter is a reduced voltage controller designed for starting standard 3 phase induction motors. Kick start and soft stop are available within both starting modes.

Designed to control acceleration and deceleration of threephase motors, the line is available for current. The power range is with an standard connections from 18,5 kw up to 560 kw 400 v and 30 kw up to 900 kw 400 v in use with an indelta connection. This feature allows easy retrofits of existing motor control. For other wiring diagrams, see ats48 user manual 1494409 on for additional information in order to size the protective and control devices, refer to the catalog on. Choosing a soft starter will increase your productivity and reduce your costs by. S811 soft starter user manual mn03902002e for more information visit. Pstx47060070 reliable in harsh environment the pstx series softstarters will lay any worries about operating in harsh conditions to rest. Also make sure you have the right power supply these starters need 10amps to close their bypass. Arrancador suave eaton s811 free download as pdf file. Easy to use digital interface module dim allows the user to configure the. This feature allows easy retrofits of existing motor control centers or enclosures and saves the expense of.

If your status light is red then your soft starter is faulted and will ignore a run command. After the motor is started, internal run bypass contactors close, resulting in the motor running directly acrosstheline. S801 soft starter user manual mn03902008e for more information visit. Getting started with altistart 48 schneider electric. C441 ethernet module user manual c441r, c441t, c441u, c441v. Soft start soft stop unit user manual schneider electric. The allenbradley controllogix 1756l84e is a controllogix controller with na io memory, 20 mb user memory, 128000 maximum io, 4000 maximum analog io, 128000 maximum digital io, and 6. S811 soft starters eaton cutlerhammer drives do supply. User manuals a comprehensive user manual is available and can be downloaded free of charge from. Lowvoltage it soft starters cited above and mediumvoltage mv801, come with soft startingstopping control and flexible protective features. The soft starter features an electronic motor overload protection feature.

1516 968 737 1489 1110 377 713 462 410 1367 233 629 907 1030 1230 584 240 311 236 844 919 637 59 775 1352 417 575 1027 1481 1214 823 1132 609 246 568 1320 1128 266 1118 872 608 683 485 1193 1298 1037